6 - Case studies

6.4 - Study of minimum tilting angle

Figure 5

Figure 6.5 - Study of a minimum tilting angle of the stops

Figure 5 shows a study explaining how the tilting angle of the oscillating stops can be limited.

This study shows the smallest tilting angle (5).

In fact, the angle of rotation (5) must be as small as possible to limit the inertial forces.

This angle is defined by the perpendicular (3) to the tangent (2) of the primitive radius (1) of the torus forming the cubic capacity of the Turbivo.

The perpendicular (3) to the tangent (2) coincides with the radius of the torus. It passes through point (4).

******



   
 